loading
A dry powder fire truck is a type of fire fighting vehicle specifically designed to extinguish fires using dry powder as the main extinguishing agent. The dry powder extinguishing agents typically consist of substances like sodium bicarbonate and ammonium phosphate, which work by inhibiting the chemical reactions of combustion.
Features and Advantages
1,Wide Applicability: Dry powder extinguishing agents can effectively put out various types of fires, including Class A (solid fires), Class B ( petroleum, gasoline, diesel, alcohol fires), Class C (gas fires), and Class E (electrical fires).Class F(oils or fats),Class K(cooking oils )
2, Rapid Extinguishing: The dry powder can quickly cover the burning material, cutting off the oxygen supply and swiftly extinguishing the flames.
3, Ease of Operation: Dry powder fire trucks are relatively simple to operate, allowing firefighters to quickly respond and manage fire incidents.
Vehicle configuration technical parameters | ||
basic parameter | Dimension | length:10580mm/height:3760mm/width2540 |
Total gross vehicle weight | 31000kg | |
Specific Power | 10.9 | |
Chassis | Model | HOWO |
Manufacturer | HOWO | |
Approach Angle/Departure Angle | 19°/13° | |
emission standard | EURO 5 | |
power | 400HP | |
crew cabin | The permitted number of passengers | 2+4 |
Air breathing apparatus seat | 4 sets | |
tilting | Dual-cylinder hydraulic tilting mechanism | |
other configuration | Multi-function steering wheel | √ |
LCD Instrument Cluster | √ | |
Electric window/centre lock | √ | |
Remote Control Key | √ | |
7-inch intelligent computer screen | √ | |
Air-conditioning | √ | |
LED Daytime Running Lights | √ | |
Mirrors electric adjustment | √ | |
Electric heated mirrors | √ | |
Fire performance parameters | ||
fire pump | Model | CB10/60 |
Installation position | rear | |
suction time | ≤50s | |
Flow rate | 60L/S@1.0Mpa | |
maximum depth | 7m | |
fire monitor | Flow rate | 48L/S |
Pressure | 1.0Mpa | |
pitch and tilt rotation angle | ─35°~ ┼70° | |
horizontal angle | 0~360° | |
jet form | Flowering and direct current | |
reaching range | 65m | |
water tank | capacity | water 6000kgs foam : 2000kgs |
material | carbon steel | |
chemical dry powder system | Dry Powder Tank | 3000KGS |
working pressure | 1..4Mpa | |
Nitrogen cylinders | 80L*8PCS | |
Rated inflation pressure | 15Mpa | |
inflation time | ≤50s | |
Effective discharge rate | 30kg/s | |
powder monitoir | 40kg/s, | |
reaching range | 35m | |
Hose reel spraying gun | 2.5kg/s | |
reaching range | 10m | |
length of hose reel | 40m | |
Pressure reducing valves | √ | |
safety valves | √ | |
Lighting electrical equipment | warning light | √ |
PA system | √ | |
Marker light | √ | |
Indicator light | √ | |
Signal light | √ | |
flashing light | √ |
Usage Scenarios
1, Chemical Plants: Suitable for extinguishing various fires in chemical plants, cincluding those involving liquid and gaseous fuels.
2, Oil Fields and Storage: Effective in quickly extinguishing fires caused by petroleum and its products in oil fields and storage facilities.
3, Airports: Used on runways and tarmacs to extinguish fires involving aircraft.
4, Electrical Facilities: Applicable for fighting fires in substations, power distribution rooms, and other electrical installations.
A dry powder fire truck is a type of fire fighting vehicle specifically designed to extinguish fires using dry powder as the main extinguishing agent. The dry powder extinguishing agents typically consist of substances like sodium bicarbonate and ammonium phosphate, which work by inhibiting the chemical reactions of combustion.
Features and Advantages
1,Wide Applicability: Dry powder extinguishing agents can effectively put out various types of fires, including Class A (solid fires), Class B ( petroleum, gasoline, diesel, alcohol fires), Class C (gas fires), and Class E (electrical fires).Class F(oils or fats),Class K(cooking oils )
2, Rapid Extinguishing: The dry powder can quickly cover the burning material, cutting off the oxygen supply and swiftly extinguishing the flames.
3, Ease of Operation: Dry powder fire trucks are relatively simple to operate, allowing firefighters to quickly respond and manage fire incidents.
Vehicle configuration technical parameters | ||
basic parameter | Dimension | length:10580mm/height:3760mm/width2540 |
Total gross vehicle weight | 31000kg | |
Specific Power | 10.9 | |
Chassis | Model | HOWO |
Manufacturer | HOWO | |
Approach Angle/Departure Angle | 19°/13° | |
emission standard | EURO 5 | |
power | 400HP | |
crew cabin | The permitted number of passengers | 2+4 |
Air breathing apparatus seat | 4 sets | |
tilting | Dual-cylinder hydraulic tilting mechanism | |
other configuration | Multi-function steering wheel | √ |
LCD Instrument Cluster | √ | |
Electric window/centre lock | √ | |
Remote Control Key | √ | |
7-inch intelligent computer screen | √ | |
Air-conditioning | √ | |
LED Daytime Running Lights | √ | |
Mirrors electric adjustment | √ | |
Electric heated mirrors | √ | |
Fire performance parameters | ||
fire pump | Model | CB10/60 |
Installation position | rear | |
suction time | ≤50s | |
Flow rate | 60L/S@1.0Mpa | |
maximum depth | 7m | |
fire monitor | Flow rate | 48L/S |
Pressure | 1.0Mpa | |
pitch and tilt rotation angle | ─35°~ ┼70° | |
horizontal angle | 0~360° | |
jet form | Flowering and direct current | |
reaching range | 65m | |
water tank | capacity | water 6000kgs foam : 2000kgs |
material | carbon steel | |
chemical dry powder system | Dry Powder Tank | 3000KGS |
working pressure | 1..4Mpa | |
Nitrogen cylinders | 80L*8PCS | |
Rated inflation pressure | 15Mpa | |
inflation time | ≤50s | |
Effective discharge rate | 30kg/s | |
powder monitoir | 40kg/s, | |
reaching range | 35m | |
Hose reel spraying gun | 2.5kg/s | |
reaching range | 10m | |
length of hose reel | 40m | |
Pressure reducing valves | √ | |
safety valves | √ | |
Lighting electrical equipment | warning light | √ |
PA system | √ | |
Marker light | √ | |
Indicator light | √ | |
Signal light | √ | |
flashing light | √ |
Usage Scenarios
1, Chemical Plants: Suitable for extinguishing various fires in chemical plants, cincluding those involving liquid and gaseous fuels.
2, Oil Fields and Storage: Effective in quickly extinguishing fires caused by petroleum and its products in oil fields and storage facilities.
3, Airports: Used on runways and tarmacs to extinguish fires involving aircraft.
4, Electrical Facilities: Applicable for fighting fires in substations, power distribution rooms, and other electrical installations.